3WL Air Circuit Breakers
7
Siemens · 2012
3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
General data
Main circuit connections – connection types
Main circuit connections
All circuit breakers are equipped with horizontal main circuit
connections on the rear for up to 5000 A as standard (horizontal
connection to busbars). Exception: Circuit breakers of size II
with max. rated current 4000 A.
Circuit breaker with a maximum rated current of 6300 A and
circuit breaker of the size II with a maximum rated current of
4000 A are equipped with vertical main connections (for upright
busbars).
The following options are available, with all combinations of
top and bottom connections possible:
Accessible from the front, single hole (for vertically installed
busbars)
Accessible from the front, double hole (holes according to
DIN 43673) (for vertically installed busbars)
At the rear, vertical (for vertically installed busbars)
Connecting flange (for direct connection to guide frame up to
4000 A).
Connection options for auxiliary circuit connections
Auxiliary circuit connections
The type of connection for the auxiliary switches depends on the
installation type:
Withdrawable version: The internal auxiliary switches are con-
nected to the male connector on the switch side. When fully in-
serted, the connector makes a connection with the sliding
contact module (see the graphic "Guide Frame" in "Design") in
the guide frame. Various adapters can then be used to com-
plete the wiring (see the graphic "Connection Options for Aux-
iliary Circuit Connections").
Fixed mounting: In this case the auxiliary supply connectors
are engaged directly onto the circuit breaker. The connectors
are equipped with
coding pins that prevent them being mistakenly interchanged.
Operator panel
The operator panel is designed to protrude from a cutout in the
door providing access to all control elements and displays with
the control cabinet door closed.
The operator panels for all circuit breakers (fixed-mounted/with-
drawable versions, 3-/4-pole) are identical. The operator panel
ensures degree of protection IP41.
Safety and reliability
The system contains many blocking devices to protect the cir-
cuit breakers and plant against unauthorized switching and to
protect maintenance and operator personnel from danger.
Others can be retrofitted.
Other safety features include:
Infeed from above or below, as required
Locking of the guide frame with the circuit breaker removed,
as standard
Locking of the withdrawable circuit breaker against move-
ment, as standard
High degree of protection with cover IP55
Mechanical reclosing lockout after overload or short-circuit
release as standard
The circuit breaker is always equipped with the required
number of auxiliary supply connectors
Standard versions
3WL circuit breakers are equipped with the following features as
standard:
Mechanical ON pushbutton and mechanical OFF pushbutton
Manual operating mechanism with mechanical closing
Switch position indication
Ready-to-close indicator
Memory status indicator
Auxiliary switch 2 NO + 2 NC
Rear horizontal main connectors for fixed mounting and for
withdrawable version up to 5000 A, and rear vertical main con-
nections at 6300 A and size II with 4000 A
For 4-pole circuit breakers, the fourth pole (N) is installed on
the left and is 100 % loadable with the rated current
Contact erosion indicator for the main contacts
Auxiliary circuit plug-in system with SIGUT screw terminals
Delivery inclusive of all auxiliary circuit connectors to internal
features including coding device for the prevention of incor-
rect installation of auxiliary supply connectors for fixed-
mounted circuit breakers
Mechanical "tripped" indicator for electronic release system
Mechanical reclosing lockout after tripping operation
Operator panel cannot be taken off with the circuit breaker in
the ON position
Additional features of the withdrawable version:
Main contacts:
Laminated receptacles in the guide frame,
penetration blades on the withdrawable circuit breaker
Position indicator in the operator panel of the withdrawable cir-
cuit breaker
Captive manual crank handle for moving the withdrawable cir-
cuit breaker
Guide frame with guide rails for easy moving of the withdraw-
able circuit breaker
The withdrawable circuit breaker can be locked to prevent it
being pushed out of position
The withdrawable circuit breaker cannot be moved when it is
in the ON position
Coding of the rated current between the guide frame and the
withdrawable circuit breaker
Standards
3WL circuit breakers comply with:
IEC 60947-2
Climate-proof according to IEC 60068-2-30.
Versions according to UL 489 also available, see Catalog LV 16.
Additional standards: www.siemens.com/lowvoltage/support or
www.siemens.com/lowvoltage/configurators.
N S
E
0
_ 0 0 9
6 7 b
N S
E 0 _
0 0 9
6 8 b
N S
E 0 _
0 0 9
6 9 b
N S
E
0
_ 0 0 9
7 9 a
N S
E
0
_ 0 0 9 6
7 b
N S
E
0
_ 0 0 9
7 0 b
N S
E
0
_ 0 0 9
7 1 b
N S
E
0
_ 0 0 9
7 2 b
N S
E
0
_ 0 0 9 7
3 b
N S E 0 _ 0 0 9 7 5 b
N S E 0 _ 0 0 9 7 6 b
© Siemens AG 2011
Seitenansicht 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 61 62

Kommentare zu diesen Handbüchern

Keine Kommentare